50683 Wrist Strap Monitoring Operation manual
(V 1.1 )
Model number:50683
First, product introduction
1.1 Product Description
According to
section 6.1.3 of ESD-S1.1, the ESD wrist strap must be tested daily unless a real-time
monitoring system is used. As described in 5.3.2.4.4 in the ESD manual TR20.20,
the ESD wrist strap must be checked every day. If the device is sensitive to
static electricity, the real-time grounding monitoring system must be used to
ensure grounding reliability.
Open the box and check whether the following items are complete:
50683 Host: one host
Power adapter: 1 (DC5V)
Remote connector: 3 PCS (including 3 cables connecting to the host)
Double string wrist strap: 3 pieces
110~220VAC to 5VDC power adapter: 1
Host ground cable: 1 (yellow or green)
Workbench cable: 3 (yellow/green 3)
Accessories bag: 1 bag
Factory inspection report
Installation and
operation instructions
1.2 Device Features
1) Can monitor the ground resistance of three wrist straps and three pads at the same time.
2) Can wirelessly transmit grounding monitoring status and numerical collection to PC for data storage, analysis and report output;
3) Using electronic monitoring principle, data accuracy within 5%, to ensure reliable grounding of monitoring objects (in line with ANSI-ESD-S20.20-2014ESD standard);
4) Compact and light, flexible installation and expansion;
5) Rewiring is not subject to personnel position adjustment;
6) With sound and
light alarm prompt function
1.3 Device Parameters:
|
Device Name: |
ESD wrist strap monitor |
|
Specifications and models: |
50683 |
|
Power Supply: |
Enter DC5V/2A |
|
Wrist strap monitoring resistance: |
The value ranges from 750 Kω to 35 Mω. The default value is 35 Mω |
|
Cushion monitoring resistance: |
The value ranges from 1 to 100MΩ. The default value is 100MΩ |
|
Operating environment: |
Anti-static workshop, -10 ~ 45℃ |
|
Maximum power consumption: |
3W |
|
Indicator status: |
Normal - green; Abnormal - red; Standby. - Orange |
|
Volume: |
120 (L) *90 (W) *35 (H) mm |
|
Weight: |
Material of 0.42 kg |
Second, product installation
Aegir50683 schematic diagram
Third, product use
After the above installation is complete, connect the power supply
and the equipment starts to work.
1) Insert the wrist strap into the jack of the extension end, do not
put the bracelet on the hand. This is the red light and alarm
2) The bracelet is worn on the wrist, when the alarm sound stops and
the green light is on
3) When you want to leave, first touch the "buckle seat"
on the extension end with your hand, and then buckle the wrist strap on the
"buckle seat" so that there will be no alarm sound, and the
corresponding indicator light is orange
Four,Equipment
Networking (optional)
Multiple 50683 devices can be networked, and monitoring records can be
displayed by remote computers. Networking legend:
All devices are connected using RJ11 twisted pair cables, each of which needs
to be connected to the computer via an RJ11-USB converter. It is recommended
that the distance from the first to the last device of a single line should not
exceed 152 meters.
The 50683 network supports the following functions:
Sets the ID number, region, and location
Sets the range of monitoring resistance. If it exceeds the range,
an alarm will be generated.
Sets the correction date
software scans the networking status of each device in real time
Record the fault
form a report
Five, product warranty
50683 Main engine warranty for one year, man-made damage is not covered by the
warranty.